VOCsmart®2000 Ion migration spectrum

Update: 2022/9/28      View:
  • Brand:    
  • Type:    VOCsmart®2000
  • Order Online
Introduction

VOCsmart®2000 Ion migration spectrum

The VOCsmart® 2000, developed by Epmonitor, the UK, uses rapid gas phase chromatography, ion migration spectroscopy and a large organic matter database to quickly analyze volatile organic compounds in liquids with a detection limit of 0.1ppb. It has the following advantages over the other detection methods:

parameter

PID

FID

GC-MS

VOCsmart®2000

usage mode,

Handheld type, light weight, small size

Large, heavy, hydrogen bottle

It's big and heavy

Small, portable, portable

Size and weight

Linearity was good at low concentrations

It is linearly throughout the range

Good linearity

Good linearity

Data linearity

5ppb~10000ppm

1~50000ppm, suitable for detection at high concentrations

0.1ppb~100ppm

0.1ppb~100ppm

Scope of detection

Detection VOC gas, certain inorganic gases

Detection of the VOC gas,

Test the VOC gas

Volatile and semi-volatile VOC can be detected

The compounds tested

Choose low-energy lamps to increase the selectivity

Very few are the few inorganic gases

Selective and highly demanding for operators

No selectivity

selectivity

has/have no influence

No selectivity

has/have no influence

has/have no influence

Influence of inert gas

After the detection of the sample, the sample can be collected for further analysis

The need to provide the oxygen is required,

The sample has been destroyed after the testing

The sample has been destroyed after the testing

Sample collection

Gas, such as methane, cannot be detected

Or the air acts as a dilution gas

A wide range of applications, and the ability to remove interference requires professional experience

Can be applied to gas, liquid and food in the VOC, strong anti-interference ability

Application scope and anti-interference ability

Reliable, long life

The sample has been destroyed after the test,

Reliable, you need to replace the consumables

Reliable, you need to replace the consumables

reliability

safe

Cannot be collected for reanalysis

Use a lot of toxic reagents, which have a certain impact on the operator

safe

safety

Low, but the detector needs to be replaced frequently

A wide range of applications, but under strong methane conditions, other VOC cannot be detected

highest

secondary

cost

not have

Frequent hydrogen flame problems and the replacement of hydrogen bottles, bring unreliability

not have

The detection results combined with the big data analysis of the cloud platform can quickly analyze the unknown samples and connect with the global fingerprint database, realize rapid qualitative and quantitative analysis, and have successful traceability application cases in foreign countries

The traceability of water source pollution

portable

explosion-proof

laboratory analysis

Both laboratory and on-board emergency environmental monitoring

Detection principle

Using rapid gas phase chromatography, ion migration spectroscopy and an organic matter database, VOCsmart® 2000 can quickly analyze volatile organic compounds in liquids, with a detection limit of 0.1ppb. Volatile organic compounds show the unique fingerprint (Fingerprint / pattern) of the test sample in a three-dimensional way. The software compares to the fingerprint with a variety of model analysis and the organic matter database in the cloud platform, so as to quickly quantify the volatile organic compounds in the liquid.

Product characteristics

1. VOCsmart® 2000 professional analysis, the professional analysis is simple, only a few steps, can be accurate qualitative and quantitative analysis, with higher detection accuracy-MS than conventional GC, less detection time, ordinary personnel can master its analysis skills after simple training.

2. Wide application range: it can be used in the analysis of volatile organic compounds in liquids and solids, and it can be compared with the organic matter fingerprint library in the cloud platform. It can be accurately analyzed, and can be qualitative and quantitative in a few minutes.

3. VOCsmart® 2000 can also be used for organic composition analysis in atmospheric PM2.5, combined with the professional air pollutant traceability system developed by EPMONITOR company, and can be applied to air pollution source traceability to meet the law enforcement needs of relevant departments.

4. Full automatic sampler

5. Single-machine operation and big data analysis are accurate, qualitative and quantitative methods

6. Heated IMS, pipe string and pipeline temperature (<80 C)

7. Purification mode

8. Users can use self-built analysis methods for specific samples: IMS temperature control, chromatography column, sampler, drift automatic calibration, and gas flow control

9. Positive / negative ionization mode can be freely switched

10. Automatic or manual operation includes: data collection, analysis, and visual presentation

11. Internal data storage, cloud platform data analysis, network data sharing and external storage interface

 technical parameter

1) Operating principle: Ion migration spectrum analysis (IMS)

2) Ionic source: ß -radiation, radioactive source (tritium (3H))

3) Radioactivity: 300 MBq, which is below the limit set by the Euratom Commission (EURATOM) 1 GBq, and is exempt from control

4) Drift voltage polarity: the positive voltage or negative voltage mode can be switched

5) Sampling method: automatic samples separated after gas phase chromatography

6) Lower limit of detection: 0.1ppb

7) Dynamic poles: 1-3, order of magnitude

8) Video device: 6.4 " TFT video view

9) Input unit: rotary pulse system

10) Processor: 400 MHz

11) Data acquisition: ultrafast ADIO-board

12) Data processing: X-board / substrate, big data analysis of cloud platform

13) Data storage: 32GB storage card

14) Transmission mode: RS232, USB, network cable interface

15) Electronic ports: 2 x D-9 pin-interface, D-15 pin (external equipment), RJ45 or SSH), 2 USB interfaces

16) Power supply: 100-240 V AC, 50-60 Hz, external power supply,

17) 24 V DC / 5A, XLR-Connector (internal supply)

18) Power: 180 watts

19) Size: 449 x 375 x 177 mm (long x width x height)

20) Weight: 15.5 kg

21) Housing: IP 67 waterproof structure, which can be used for outdoor analysis, EMC certification

22) Vent ventilation interface: 3 mm stainless steel interface

23) Full automatic sampler

24) Features: temperature control box, mixing and heating automatic sampler

25) Sample capacity of automatic sample feeder: standard 32 tubes, optional 96 tubes (10 or 20 mL)

26) Operation: there are four function keys, icon and rolling operation button

27) Size: 828 x 385 x 648 mm (WxDxH)

28) Weight: 10 kg

Data analysis and application of VOCsmart® 2000

Using the VOCsmart® 2000 analysis software designed by Epmonitor, it is easy to learn and icon-based in only a few steps

1) Measurement data: After collecting the IMS gas analysis of the sample, the IMS fingerprint map shows the components of different compounds contained in the sample.

2) After learning to manually select the main parameters from the map, using these parameters can be analyzed again to classify and identify the unknown samples

3) Prediction / classification: Under the prediction mode, the fingerprint library of different organic matter stored in the cloud platform can be used to compare, quickly analyze the type and concentration of samples, and qualitatively determine the sample source.